logo
Send Message
Guangzhou Xinlin Fire Fighting Equipment Co., Ltd.
products
Cases
Home >

China Guangzhou Xinlin Fire Fighting Equipment Co., Ltd. Company Cases

Testing the FM200 gas extinguisher equipment leakproofness in the water

    Applications   1. Data Centers and Server Rooms: The FM200 Clean Agent is perfect for protecting sensitive electronic equipment from fire damage. It works by releasing a gas that quickly extinguishes the flames without damaging the equipment or leaving any residue behind.   2. Telecommunications Facilities: Telecommunications equipment is vulnerable to fire damage, which can cause significant downtime and financial losses. The FM200 Clean Agent is the ideal solution for protecting these facilities, as it can quickly extinguish fires without damaging the equipment or disrupting operations.   3. Museums and Art Galleries: The FM200 Clean Agent is safe for use around valuable artwork and artifacts, as it leaves no residue and does not damage the items it protects. It is also non-toxic and does not pose a risk to human health.   4. Medical Facilities: Hospitals and other medical facilities require fire protection that is safe for patients and staff. The FM200 Clean Agent is non-toxic and safe for use in these settings, making it an ideal choice for protecting critical medical equipment and facilities.   5. Industrial Facilities: The FM200 Clean Agent is effective for use in a variety of industrial settings, including manufacturing plants, warehouses, and chemical storage facilities. It can quickly extinguish fires without damaging equipment or causing harm to workers. Overall, the FM200 Clean Agent from Guangzhou Xingjin Fire Equipment Co.,Ltd. is a highly effective fire extinguishing agent that is safe, non-toxic, and leaves no residue. It is ideal for use in a variety of settings, including data centers, museums, medical facilities, and industrial settings. Its high safety level and low moisture ppm make it a reliable choice for fire protection needs.   Transport packaging of this product is done using Plywood Outer Boxes with Bubble Bags or Paper, ensuring safe delivery to the customer. The product is clear in appearance and has a boiling point of -16.5, making it highly effective in extinguishing fires.  

Goods for Customer in Papua New guinea

  PRODUCT DESCRIPTION   Cafss Automatic Novec 1230 Fire Suppression System Without Pollution For Telecommunication Room   Similar to heptafluoropropane fire extinguishing system, PFH fire extinguishing system is also divided into pipe network fire extinguishing system and prefabricated fire extinguishing system. The pipe network fire extinguishing system is mainly composed of fire extinguishing agent steel cylinder, drive cylinder, selector valve, collecting pipe, control pipeline, signal feedback device, leak detection device, pipeline, nozzle, etc. The fire extinguishing agent and high pressure nitrogen are stored in the steel cylinder. When the system starts to extinguish fire, the cylinder head valve and the selector valve are opened. The gas fire extinguishing agent is driven by high pressure gas through the pipeline, ejected from the nozzle, rapidly gasified, and extinguished through heat absorption and cooling. According to the number of protection zones, it can be divided into unit independent system and combined distribution system. Prefabricated fire extinguishing system is a fire extinguishing system with linkage control function, which is designed and assembled according to certain application conditions, such as extinguishing agent storage device and spraying components. Prefabricated fire extinguishing system, also known as cabinet gas fire extinguishing device, is composed of fire extinguishing agent cylinder, pipeline, nozzle, signal feedback component, leak detection component, drive component, etc  

Goods for Customer in Uzbekistan

Goods for Customer in Uzbekistan dynamo room Advantage   1. Heptafluoropropane is a gaseous fire extinguishing agent, which has no residue, is not conductive, and generally does not cause secondary pollution (compared with the ashen face of dry powder fire extinguishers after use). It is a good fire extinguishing agent for extinguishing electronic equipment, precision instruments and equipment, valuable instruments and archives, and other paper, silk or magnetic media material information carriers;   2. Within the designed fire extinguishing concentration (not less than 1.3 times of the fire extinguishing concentration), there is basically no adverse effect on human body (IG541 and carbon dioxide are toxic under the fire extinguishing concentration), and can be used in places where people stay (carbon dioxide fire extinguishing system is not allowed);   3. During the fire extinguishing process, the fire extinguishing speed is faster than that of carbon dioxide and IG541, which are the same gas extinguishing agents, and the fire extinguishing concentration and inerting concentration are lower than that of carbon dioxide and IG541. Therefore, for the same fire, the number of steel cylinders required for the gas fire extinguishing system is small, the floor space is small, and the layout requirements are low. The cabinet fire extinguishing system can be used for flexible installation (compared with IG541 and carbon dioxide fire extinguishing system, which require more steel cylinders to provide sufficient fire extinguishing capacity).   4.The fire extinguishing time of heptafluoropropane is generally completed within 1min, and there is no re-combustion after completion (asphyxiant fire extinguishing agent is prone to re-combustion).     Application   Electronic computer room, a data processing center, telecommunications facilities, process control, expensive medical equipment, industrial equipment, library, museum and art gallery, clean room, anechoic chamber, emergency power facilities, flammable liquid storage area, etc.   The place where the fire is easy to happen, like paint-spraying production line, aging-electrical equipment, rolling machine, printing machine, oil switch, oil immersed transformer, melt impregnating tank, tank, large generators, drying equipment, cement pro duction process of pulverized coal, and the ship's engine room, cargo hold, etc.  

Goods for Customer in Mongolia

Goods for Customer in Mongolia PRODUCT DESCRIPTION Cafss 1.6Mpa FM200 Fire Suppression Extinguisher No Remains For Data Center   It's an environment protection, good electrical insulation and great efficiency in extinguishing fire, widely used in the fire protection of power distribution, archive rooms, transforming houses,computer rooms,etc.Our FM200 fire suppression system show the characteristics advancing technologies, easy operation, good structure,and convenient maintenance,etc.   The propane heptafluoride fire firefighting system of our company has the advantages of complete designed parameters, perfect functions, accurate and reliable operation, non-leakage in long-term storage, simple installation and commissioning, and convenient operation and maintenance. The system is mainly composed of auto alarm controller, reservoir, valve driving device, selector valve, non-return valve, pressure signaler, frame, spraying nozzle and ductwork. Unit independent system and combination allocation system may be composed according to the application requirement for fire protection of one area and several areas respectively. It is applicable to the fire protection of many important places such as computer room, telecommunication center, underground works, petroleum extraction on the sea, library, archives, treasure house and power distribution   Parameters   No. Specifications Parameters 1 Tank size 8Ltr, 10Ltr, 16Ltr, 20Ltr, 30Ltr 2 Device model XQQW8/1.6, XQQW10/1.6, XQQW16/1.6, XQQW20/1.6, XQQW30/1.6 3 Storage pressure 1.6MPa 4 Maximum working pressure 2.5MPa 5 Discharge time ≤10s 6 Maximum filling Density 1 kg/L 7 Activating Temperature 68℃ 8 Ambient working Temperature 0℃~50℃   Below data refers to regular temperature at 20 centigrade and atmospheric pressure at 1 bar. The max coverage would vary a little from the ambient temperature and pressure on the real condition.   Device model Filling amount (kg) Maximum working pressure(MPa) Storage pressure (MPa) Maximum coverage(m³) Starting mode XQQW8/1.6 8 2.5 1.6 11.11 temperature sensor Activating Temperature: 68℃ XQQW10/1.6 10 2.5 1.6 13.89 XQQW16/1.6 16 2.5 1.6 22.22 XQQW20/1.6 20 2.5 1.6 27.78 XQQW30/1.6 30 2.5 1.6 41.67     Components   One spherical pressure tank, fire extinguishing agent(HFC-227ea, same as FM200), hanging mounting, thermal sensor(one little glass tube filled with liquid whose volume will be changed by temperature).   The goods are shipped to Mongolia.The models is GQQ100/2.5 cabinet type of FM200 fire extinguishing system.   FEATURES Specifications Cylinder Volume: 8L, 10L,16L, 20L, 30L Pattern Of Extinguishing: Enclosed Flooding Agent: HFC-227ea(FM200) Working Pressure: 1.6MPa Color: Red High Light: FM200 Fire Suppression Extinguisher , Data Center Fire Suppression Extinguisher , 1.6Mpa Fire Suppression Extinguisher Basic Infomation Place of Origin: China Brand Name: Air Giant Certification: CAL,CMA,CNAS,ILAC-MRA,CCC Model Number: XQQW8/1.6, XQQW10/1.6, XQQW16/1.6, XQQW20/1.6, XQQW30/1.6 Payment & Shipping Terms Packaging Details: Plywood outer box with bubble bag or paper Delivery Time: 10-15 working days Payment Terms: L/C , D/P, T/T, Western Union, Paypal, Credit card Supply Ability: 28000 sets per week  

How to budget the mechanical part of hanging or cabinet type of fm200 fire suppression system?

How to budget the mechanical part of hanging or cabinet type of fm200 fire suppression system? Steps: 1. calculation of fm200 gas(if you have got the quantity of fm200 gas, this step can be neglected) Two things should be considered:   One, the dimension or volume or length and width and height of the protection zone;   Two, the type of protection zone. (Different type of protection zone need different design density of fm200 gas) Computer room or communication center or archive or museum or generator or transfer station etc.     2. Choice of container One thing should be considered and one principle should be complied with. As you can see, here we have different models and many sizes for each model, such as electricity-controlled and temperature-controlled hanging type and cabinet type.   Electricity-controlled type of fm200 system For this model, we have 16liters and 20liters and 30liters and 40liters and 50liters. Temperature-controlled type of fm200 system For this model, we have 4/6/8liters and 10liters and 30liters.   Cabinet type of fm200 system For this type, we have 40liters and 70liters and 90liters and 100liters and 120liters and 150liters and 180liters.   You should consider which model is better. Considering the installation and space, the temperature-controlled one is absolutely simplest and easiest. You just need to fasten it to the ceiling. Because we have filled the gas and offered the accessories to fix the device. And the actuating temperature is around 68℃.So this type is the best choice for little room. But if the protection is bigger, you can consider about the cabinet type or multiple electricity-controlled type. Because if there is no too much space for extinguishing device, the hanging type can function. Then if the protection zone need multiple spots to be monitored. You should consider the electricity-controlled type of cabinet type. Because they will connect with alarm system where you can arrange multiple detectors according to your real requirement.   Maybe you donot know which size is proper for your choice. So here is a principle: The max filling quantity of fm200 gas is almost equal to the value of volume of cylinder. That means the max filling quantity of 16liters cylinder is close to 16kg fm200 gas. So that you can choose the cylinder according to the quantity of fm200 form step 1.   In general,you just need offer the details of protection zone. We can reply to you with a relevant accurate quotation. Of course, according to step above, we can make an example here. If the protection zone is a electricity and 40 cubic meter, then the necessary extinguishing agent after calculation is 28.8kg. Then according to the principle of step2, we can choose the 30liters tank. Then the budget is clear now.   Pipe network type of fm200 system is more popular in big project or multiple zones which are connected or near by. Of course, it will be very complicated to make an accurate budget. The product above can be estimated by yourself sometimes. But for pipe network type of fm200 system, you can handle the project to us overall. We need to design and calculate all the accessories, then we can give you an exact quotation.  
1 2 3