Data Center / IDC Room–Specific Fire Protection Solutions
Release Date:
2026-07-23
(1) Applicable Scenarios
Cloud computing centers, operator IDC data halls, bank data centers, server rooms, UPS battery rooms, telecommunications switch rooms, and building high-voltage distribution rooms.
(II) Pain Points of Fire Safety in Venues
1. Servers and switching equipment are expensive to procure, and water‑sprinkler or dry‑chemical fire suppression systems can easily cause circuit board short circuits and metal corrosion, leading to the complete scrapping of the equipment and substantial financial losses.
2. The data center operates continuously 24/7; a fire‑induced shutdown would result in service disruption, necessitating zoned, independent fire suppression to prevent cross‑zone accidental discharge.
3. UPS battery compartments are prone to thermal runaway and spontaneous combustion, with rapid fire spread and a high risk of cascading propagation.
4. The data center features multi‑level zoning and spans a large protective volume, necessitating centralized, intelligent, interconnected management and control.
(3) Configuration of Supporting Products
1. Large‑space protection for main computer rooms: an externally pressurized piped‑network type heptafluoropropane fire suppression system (combined distribution type, with a shared cylinder room serving multiple protected zones, resulting in lower costs);
2. Independent small computer rooms and precision equipment areas: cabinet-type prefabricated perfluorohexanone fire suppression systems;
3. Point‑of‑use protection inside UPS cabinets and servers: perfluorohexanone automatic fire‑extinguishing module for detection tubes;
4. Personnel‑occupied control room: IG541 mixed‑gas fire suppression system;
5. On-site emergency handheld equipment: stainless steel portable perfluorohexanone fire extinguisher;
6. Intelligent Early-Warning and Interlinked System: very early‑stage aspirating smoke detectors, gas fire suppression controllers, an IoT‑based smart fire‑protection cloud platform, and an electrical fire monitoring system.
7. Large-area open-flame emergency response equipment: an intelligent, remotely controlled firefighting robotic dog.
(IV) Core Advantages of the Plan
1. The entire product line uses clean extinguishing agents, leaving no water accumulation, no dust, and no acidic residues; equipment in the data center can be restarted shortly after fire suppression.
2. Zone‑independent discharge control logic prevents accidental activation in adjacent rooms, thereby minimizing downtime and associated losses.
3. Free on-site survey at your location, precise calculation of protection volume, and preparation of professional CAD-based pipeline network construction drawings.
4. All equipment is manufactured in our own factory, and installation is carried out by a licensed, professional construction team, ensuring that the existing data center’s low-voltage cabling remains undisturbed throughout the process.
5. Long-term after-sales support, including regular hydrostatic testing of cylinders, agent refilling, system integration and commissioning, and year-round on-site maintenance services.