Send Message
Guangzhou Xinlin Fire Fighting Equipment Co., Ltd.
products
news
Home >

China Guangzhou Xinlin Fire Fighting Equipment Co., Ltd. Company News

High quality with good price.

2%percent difference, probably due to service 5'% percent difference. I think it's workmanship 10% difference. Must be materials The price difference of 20% is not an order of magnitude The age of transparency and thin margins Please give your time to someone who knows what you're doing and is reliable. PRODUCT DESCRIPTION Piston Flow Type FM200 Gas Suppression System   The use of FM200 fire extinguishing agent as a fire suppressant is not prohibited by the montreal protocol. It is a clean agent that belongs to a class of compounds that was introduced specifically to facilitate the phase-out of ozone depleting gases, such as Halon 1301. It is the most widely used of the chemical replacements for Halon 1301. It is an agent that has been used successfully to help protect tens of thousands of high technology facilities in 70 countries around the world.   FM200 gas piston flow type fire suppression systems can be ideal for use in occupied areas. Independent toxicity studies have established that the agent is low in both acute and chronic toxicity with high safety margins between its normal use concentrations and the no observable adverse effect level (NOAEL).     Parameters   No. Name Specification 1 Device Model QMQ5.6/90W, QMQ5.6/120W, QMQ5.6/150W, QMQ5.6/180W, QMQ4.2/245W 2 Cylinder Volume 90Ltr, 120Ltr, 150Ltr, 180Ltr, 245Ltr 3 Filling Capacity of Gas 112.5kg, 150kg, 187.5kg, 225kg, 306.25kg 4 Max Working Pressure 8MPa, 5.3MPa 5 Max protected area Single zone: 800m2 6 Max protected volume Single zone: 3600m3 7 Spraying Time ≤10s 8 Agent Filling Density ≤1250kg/m3 9 Power DC24V/1A 10 Pressure of Adding Pressure Cylinder 13.5MPa 11 Pressure of Driving Device 6.0MPa(20℃) 12 Condition of Reserving Room for Container Temperature: 0~50℃     System Composition   This system mainly consists of agent storage cylinder, container valve, driving cylinder group, adding pressure cylinder group, distributing valve, liquid flow check valve, gas flow check valve, safety valve, pressure switch, frame, nozzle, high pressure hose, pressure-relief device, level gauge, relief valve, pipe system, which can constitute the unit independent system. Combined distribution system and other forms can implement fire protection for single and multiple zones.   Pipe fittings are those conduits to connect extinguishing device and guide agent into protective zone, like high pressure galvanized steel pipe and flange and elbow.   Electrical accessories are those things which are used to detect and monitor whole protective area and control whole system, also warn people to evacuate and prevent from fire expansion.   These integrated three parts will be efficient to detect and supervise and alarm and extinguish fire automatically.

2024

05/10

Goods for Customer in Cambodia

Goods for Customer in Cambodia Packages   We always pack it with polyfoam first and then put it into a wooden case. Sometimes, in order to meet with customers or the safety requirement, we will make a pallet for the goods.   Advantage   1. Heptafluoropropane is a gaseous fire extinguishing agent, which has no residue, is not conductive, and generally does not cause secondary pollution (compared with the ashen face of dry powder fire extinguishers after use). It is a good fire extinguishing agent for extinguishing electronic equipment, precision instruments and equipment, valuable instruments and archives, and other paper, silk or magnetic media material information carriers;   2. Within the designed fire extinguishing concentration (not less than 1.3 times of the fire extinguishing concentration), there is basically no adverse effect on human body (IG541 and carbon dioxide are toxic under the fire extinguishing concentration), and can be used in places where people stay (carbon dioxide fire extinguishing system is not allowed);   3. During the fire extinguishing process, the fire extinguishing speed is faster than that of carbon dioxide and IG541, which are the same gas extinguishing agents, and the fire extinguishing concentration and inerting concentration are lower than that of carbon dioxide and IG541. Therefore, for the same fire, the number of steel cylinders required for the gas fire extinguishing system is small, the floor space is small, and the layout requirements are low. The cabinet fire extinguishing system can be used for flexible installation (compared with IG541 and carbon dioxide fire extinguishing system, which require more steel cylinders to provide sufficient fire extinguishing capacity).   4.The fire extinguishing time of heptafluoropropane is generally completed within 1min, and there is no re-combustion after completion (asphyxiant fire extinguishing agent is prone to re-combustion).     Application   Electronic computer room, a data processing center, telecommunications facilities, process control, expensive medical equipment, industrial equipment, library, museum and art gallery, clean room, anechoic chamber, emergency power facilities, flammable liquid storage area, etc.   The place where the fire is easy to happen, like paint-spraying production line, aging-electrical equipment, rolling machine, printing machine, oil switch, oil immersed transformer, melt impregnating tank, tank, large generators, drying equipment, cement pro duction process of pulverized coal, and the ship's engine room, cargo hold, etc.      

2024

04/22

Goods for Customer in Myanmar

Goods for Customer in Myanmar ready to ship   Advantage   1. Heptafluoropropane is a gaseous fire extinguishing agent, which has no residue, is not conductive, and generally does not cause secondary pollution (compared with the ashen face of dry powder fire extinguishers after use). It is a good fire extinguishing agent for extinguishing electronic equipment, precision instruments and equipment, valuable instruments and archives, and other paper, silk or magnetic media material information carriers;   2. Within the designed fire extinguishing concentration (not less than 1.3 times of the fire extinguishing concentration), there is basically no adverse effect on human body (IG541 and carbon dioxide are toxic under the fire extinguishing concentration), and can be used in places where people stay (carbon dioxide fire extinguishing system is not allowed);   3. During the fire extinguishing process, the fire extinguishing speed is faster than that of carbon dioxide and IG541, which are the same gas extinguishing agents, and the fire extinguishing concentration and inerting concentration are lower than that of carbon dioxide and IG541. Therefore, for the same fire, the number of steel cylinders required for the gas fire extinguishing system is small, the floor space is small, and the layout requirements are low. The cabinet fire extinguishing system can be used for flexible installation (compared with IG541 and carbon dioxide fire extinguishing system, which require more steel cylinders to provide sufficient fire extinguishing capacity).   4.The fire extinguishing time of heptafluoropropane is generally completed within 1min, and there is no re-combustion after completion (asphyxiant fire extinguishing agent is prone to re-combustion).     Application   Electronic computer room, a data processing center, telecommunications facilities, process control, expensive medical equipment, industrial equipment, library, museum and art gallery, clean room, anechoic chamber, emergency power facilities, flammable liquid storage area, etc.   The place where the fire is easy to happen, like paint-spraying production line, aging-electrical equipment, rolling machine, printing machine, oil switch, oil immersed transformer, melt impregnating tank, tank, large generators, drying equipment, cement pro duction process of pulverized coal, and the ship's engine room, cargo hold, etc.    

2024

04/22

1 2 3 4