Hanging dry‑powder fire extinguishers are equipped with a heat‑sensitive glass bulb at the nozzle of the spray head. When the temperature reaches a preset threshold, the bulb breaks, and the internal pressure of the extinguisher forces the dry powder to be discharged through the spray head, thereby extinguishing the fire. This product features rapid extinguishing, a compact and aesthetically pleasing design, and exceptional performance.

Hanging dry‑powder fire extinguishers are equipped with a heat‑sensitive glass bulb at the sprinkler nozzle. When the temperature reaches a preset threshold, the bulb breaks, and the internal pressure of the extinguisher forces the dry powder to spray toward the nozzle, thereby suppressing the fire. These products feature rapid extinguishing, a compact and aesthetically pleasing design, and exceptional performance. They deliver significantly faster response times than conventional portable extinguishers and are typically used in distribution rooms, chemical storage facilities, small warehouses, and similar settings.

The protected area of a suspended dry‑powder fire extinguisher is typically calculated as 10 square meters, with a protection radius of 3 meters; if the installation location is relatively high, the effective protected area will be reduced accordingly. Suspended dry‑powder fire extinguishers are available in four operating temperature ratings: 57°C, 68°C, 79°C, and 93°C.

The installation of suspended dry‑powder fire extinguishers is straightforward. Determine the number of extinguishers based on the available space, and mount the units from the ceiling at a height not exceeding five meters. Refer to the installation diagram during installation.

 

Model and Protection Area of County‑Mounted Dry Powder Fire Extinguishers

Specification Model

Fire extinguishing rating

Protection radius

Protected area

Note

6 kg hanging dry powder fire extinguisher

3A, 89B

≥0.94

17m3

 

8 kg suspended dry powder fire extinguisher

3A, 113B

≥1.07

22m3

 

10 kg hanging dry powder fire extinguisher

4A, 144B

≥1.13

28m3

 

 

Installation Diagram for Suspended Dry Powder Fire Extinguishing System

More products

The company’s core offerings include: clean‑gas fire suppression systems, with one‑stop services for design, manufacturing, installation, and maintenance; heptafluoropropane (FM‑200, HFC‑227ea) fire suppression systems; Novec 1230 (perfluorohexanone) clean‑gas fire suppression systems; IG‑541 mixed‑gas and IG‑100 nitrogen fire suppression systems; high‑pressure piped‑network carbon dioxide (CO₂) fire suppression systems; and intelligent gas‑based fire alarm control panels.