How to Choose a Fire Extinguisher for Different Types of Fires

2026-08-25


For Class A fires, fire extinguishers such as water-based, foam, dry chemical, and halon types should be used.

When selecting a fire extinguisher, the following requirements shall be met:

1. For extinguishing Class A fires, water-based, foam, dry chemical, and halogenated hydrocarbon fire extinguishers should be used.

2. For Class B fires, dry chemical, foam, halon, and carbon dioxide extinguishers should be used; chemical foam extinguishers must not be used to fight water‑soluble Class B fires.

3. For Class C fires, dry chemical, halon, or carbon dioxide fire extinguishers should be used.

4. When extinguishing fires involving energized equipment, halon, carbon dioxide, or dry chemical fire extinguishers should be used.

5. For fires involving Class A, B, C materials and energized electrical equipment, dry chemical or halon fire extinguishers should be used.

6. For Class D fires, a dedicated dry powder fire extinguisher should be used.

Types of fire extinguishers and their intended applications:

1. For extinguishing fires involving cultural relics and archives, carbon dioxide, carbon tetrachloride, 1211, bromodifluoromethane, 2402, 1301, heptafluoropropane, and hexafluoropropane should be used.

2. For extinguishing flammable liquids, dry chemical, carbon dioxide, carbon tetrachloride, 1211, bromochloromethane, 1301, 2402, heptafluoropropane, hexafluoropropane, and alcohol-resistant foam should be used.

3. For extinguishing flammable gases, use dry powder, carbon dioxide, carbon tetrachloride, 1211, bromodifluoromethane, 1301, 2402, heptafluoropropane, and hexafluoropropane.

4. For fires involving electrical equipment, dry powder, carbon dioxide, carbon tetrachloride, 1211, bromodifluoromethane, 1301, 2402, heptafluoropropane, and hexafluoropropane should be used.

5. For fires involving precision instruments, carbon dioxide, carbon tetrachloride, 1211, bromodifluoromethane, 1301, 2402, heptafluoropropane, and hexafluoropropane should be used.

For more information on fire suppression systems, please visit www.gzxlxf.com or call our hotline at 020-8168-3136.

Previous article:

More products

The company’s core offerings include: clean‑gas fire suppression systems, with one‑stop services for design, manufacturing, installation, and maintenance; heptafluoropropane (FM‑200, HFC‑227ea) fire suppression systems; Novec 1230 (perfluorohexanone) clean‑gas fire suppression systems; IG‑541 mixed‑gas and IG‑100 nitrogen fire suppression systems; high‑pressure piped‑network carbon dioxide (CO₂) fire suppression systems; and intelligent gas‑based fire alarm control panels.